Rotor lid for FA-6x50

Catalog nr. 5895151000
Eppendorf

Price:
Sale price€264,44
Ask quote for bulk order

Description

Rotor lid for FA-6x50 is an aerosol-tight aluminium lid designed specifically for the FA-6x50 rotor used with Centrifuge 59xx series instruments. As a dedicated replacement or spare cover, it restores the closed, aerosol-tight configuration of the rotor so that samples can be centrifuged under the containment conditions intended for that rotor system. Aluminium construction provides a durable, laboratory-ready fit for repeated use in high-throughput and routine centrifugation workflows. The lid is matched to the FA-6x50 geometry and supports secure closure during operation on compatible Eppendorf centrifuges in the 59xx family. Supplied as a single piece from manufacturer Eppendorf, it is a practical accessory for laboratories that already operate FA-6x50 rotors and need a matching aerosol-tight lid for maintenance, spare stocking or continued safe handling of sensitive or hazardous samples. Clear rotor-specific designation helps ensure correct pairing with the FA-6x50 rotor in daily laboratory practice.

This article belongs on Rotors, in Centrifuges.

Key features

  • Pack size: 1 pc(s)
  • Product type: Rotor lid
  • Compatible rotor: FA-6x50
  • Property: Aerosol-tight
  • Material: Aluminium
  • Compatibility: Centrifuge 59xx series

Recently viewed

You may also like

Questions about Rotor lid for FA-6x50

What is this article?

Rotor lid for FA-6x50 is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?