Rotors

Here you will find everything your laboratory needs for rotors, such as: centrifuge, rotor, centr and rotor angle. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 595 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

375 products

Showing 1 - 24 of 375 products

Showing 1 - 24 of 375 products
View
Angle rotor, 4 strips with 8 PCR tubes each, for model R24, Labbox, art. CCANA13001Labbox
Rotor S-96x0,2-PCR for Centrifuge 5425/R, Eppendorf, art. 5495512004Eppendorf
Form insert 15 ml Falcon, packed (8×), Eppendorf, art. 5702702005Eppendorf
Rotor A-4-44 with 4 carriers 2x50 Falcon, Eppendorf, art. 5804719000Eppendorf
Swing-out rotor for 4 × 50 ml tubes, for Flow Multi, Labbox, art. CCANA03001Labbox
Fixed-angle rotor for 4 x 50 ml tubes, for Flow Multi, Labbox, art. CCANA07001Labbox
Swing-out rotor for 16 × 15 ml tubes, for Flow Multi, Labbox, art. CCANA02001Labbox
Fixed-angle rotor for 16 x 15 ml tubes, for Flow Multi, Labbox, art. CCANA06001Labbox
Fixed-angle rotor for 24 x 15 ml tubes, for Flow Multi, Labbox, art. CCANA09001Labbox
Angle rotor for max. 24 × 1.5/2,0 ml, Hettich, art. 3L99.1Hettich
Round buckets S-4x1000, set of 4, Eppendorf, art. 5895102000Eppendorf
Swing-out rotor 6x5 ml RB, Ohaus, art. 30130880Ohaus
Ohaus Rotor Swing out 6x5ml RB
Sale price€484,00
Rotor S-4xUniversal-Large, incl. buckets, Eppendorf, art. 5895190006Eppendorf
Swing-out rotor 4x100 ml ID sealable, Ohaus, art. 30314823Ohaus
Swing-out rotor 4 × 1000 ml ID sealable, Ohaus, art. 83041512Ohaus
Rotor S-4x750 incl. round buckets, Eppendorf, art. 5895120008Eppendorf
Swing-out rotor 4 x 750 ml ID sealable, Ohaus, art. 30553085Ohaus
Rotor S-4x1000 incl. plate/tube buckets, Eppendorf, art. 5895117007Eppendorf

Recently viewed

Questions about Rotors

Fixed-angle or swing-out rotor: what is the difference?

In a fixed-angle rotor the tubes sit at a constant angle: higher g-force, short run times and a pellet against the tube wall. In a swing-out rotor the buckets swing to horizontal, so the pellet forms at the bottom and layers separate sharply, which suits blood and gradients, and larger volumes. With the right adapters, swing-out buckets often also take plates or larger bottles. See rotor adapters and accessories and centrifuge. Questions about a specific product? Contact sales@luminixhealth.com.

Will this rotor fit my centrifuge?

Rotors are specific to an instrument. Check the compatible centrifuge model on the product page and in the manual of your centrifuge, and never use a rotor from another instrument, even if it seems to fit. If in doubt, include the model and serial number of your centrifuge when you ask us for a quotation. Respect the maximum speed of the rotor. Instruments are in benchtop and floor-standing centrifuges. Unsure which one fits? Ask sales@luminixhealth.com.

Do I need an aerosol-tight rotor or lid?

With infectious or hazardous material, an aerosol-tight rotor or a bucket with a sealed lid keeps aerosols contained if a tube breaks during the run. Open such rotors and buckets in a safety cabinet, not on the open bench. Check on the product page whether the tightness is certified. Replace sealing rings at the interval given in the manual, because worn seals no longer keep aerosols in. Rotors and lids are in rotors; see also centrifuge tube. Need advice for your set-up? Mail sales@luminixhealth.com.

Which adapters do I need for my tubes?

Adapters reduce the opening of a bucket or rotor bore so smaller tubes, or plates, fit securely. Choose them by tube volume, bottom shape (conical or round) and the number of positions. Always load the rotor symmetrically, with equal weights opposite each other. Adapters must match the rotor model exactly. Check the tube dimensions on the product page before you order. See rotor adapters and accessories and centrifuge tubes. For a quote or a second opinion, write to sales@luminixhealth.com.

Why Rotors?

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

This shelf belongs to Centrifuges, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?