Viscosimeter ASTM D445 D446 0,6-3,0mm²/s

Catalog nr. 8589102
Witeg

Price:
Sale price€240,75
Ask quote for bulk order

Description

ASTM D445 and D446 viscometer, size No. 0c, is a calibrated three-legged capillary instrument for kinematic viscosity measurement of transparent liquids in the range 0,6–3 mm²/s. With capillary constant K 0,003 and an approximate length of 283 mm, it is adjusted for use under ASTM D445/D446 as well as ISO 3104 and ISO 3105. The three-legged geometry supports stable mounting and clear observation of the meniscus during efflux timing on clear fluids. This model is stated as identical to sample SI No. 501.03, giving laboratories a defined reference match for method alignment and instrument selection. Supplied as 1 pc with a net weight of 0,08 kg, the calibrated unit from manufacturer Witeg is intended for transparent liquids in routine analytical and quality-control viscosity work. The combination of size No. 0c, constant K 0,003 and the 0,6–3 mm²/s window helps keep low-viscosity samples within the recommended measuring band. Laboratories following ASTM or ISO capillary procedures can deploy this adjusted instrument directly in a suitable temperature-controlled bath without altering the stated geometric or calibration parameters.

This article is part of Viscometers, in Density & viscosity measurement.

Key features

  • Pack size: 1 pc
  • Standards: ASTM D445, D446, ISO 3104, ISO 3105
  • Size number: No. 0c
  • Constant K: 0,003
  • Measuring range: 0,6–3 mm²/s
  • Length: approx. 283 mm, three-legged

Recently viewed

You may also like

Questions about Viscosimeter ASTM D445 D446 0,6-3,0mm²/s

What is this article?

Viscosimeter ASTM D445 D446 0,6-3,0mm²/s is the article on this page. Luminix Health distributes Witeg for laboratory use. It sits in Viscometers, inside Density & viscosity measurement, in Lab instruments.

A capillary viscometer times the flow of a liquid through a tube. A rotational viscometer twists a spindle in the liquid. Both need a stated temperature. Kinematic and dynamic viscosity are different numbers. The capillary size has to put the flow time in the range the method allows.

Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.

Which category should I open next?

The category is Density & viscosity measurement. The sub-category is Viscometers. The catalogue is Lab instruments.

Shelves beside this one are Hydrometers and Density meters & pycnometers.

What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?