Vacuum pumps

Here you will find everything your laboratory needs for vacuum pumps, such as: vacuum pump, paket, select and vacuum-safety-suction. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 567 articles. The catalogue holds more than 150.000 articles. We deliver across the EU, usually within 2 to 5 working days.

567 products

Showing 25 - 48 of 567 products

Showing 25 - 48 of 567 products
View
Sartolab® P20 Diaphragm Laboratory Pump, Sartorius, art. 180MP1Sartorius
Sartorius Diaphragm Laboratory pump
Sale price€1.640,00
Rocker 440 compressed air system 230 V, Witeg, art. 0082916744022Witeg
Rocker 410 oil-free vacuum pump 230 V, Witeg, art. 0082916741022Witeg
Rocker 430 oil-free vacuum pump 230 V, Witeg, art. 0082916743022Witeg
Rocker 400 oil-free vacuum pump 120 V, Witeg, art. 0082916740011Witeg
Rocker 410 oil-free vacuum pump 120 V, Witeg, art. 0082916741011Witeg
Rocker 400 oil-free vacuum pump 230 V, Witeg, art. 0082916740022Witeg
Rocker 300 DC oil-free vacuum pump 12 V, Witeg, art. 0082916733000Witeg
Rocker 300 oil-free vacuum pump 230 V, Witeg, art. 0082916730022Witeg
Rocker 300 oil-free vacuum pump 120 V, Witeg, art. 0082916730011Witeg
PC 3004 VARIO select EKPVacuubrand
Vacuubrand PC 3004 VARIO select EKP
Sale price€9.865,00
PC 3012 NT VARIO select vacuum systemVacuubrand
PC 3010 NT VARIO select vacuum systemVacuubrand
Service kit for MPC 301 Zp Ex (Cat 2), WELCH, art. 402038_44WELCH
Laboratory vacuum pump, 110 V, 60 Hz, Sartorius, art. 16615_26Sartorius
SartoJet Membrane Pump, Sartorius, art. 17521110Sartorius
Sartorius Sartojet membrane pump
Sale price€16.210,00
Handle for BioDolphin / BioVac, Witeg, art. 0082919910030Witeg
Vacuum hand pump with vacuum gauge, 625 mmHg, Labbox, art. VACUH02001Labbox
Sampling head, triclamp version, for active air monitoring with the MD8 Airscan®, Sartorius, art. 1674601SHTSartorius

Recently viewed

Questions about Vacuum pumps

Diaphragm pump, rotary vane pump or water jet pump: which vacuum pump suits me?

A diaphragm pump runs oil-free, needs little maintenance and suits filtration, rotary evaporation and drying ovens, such as the diaphragm laboratory pump; for evaporators, see rotary evaporators. A rotary vane pump reaches a deeper vacuum, needed for freeze-drying or vacuum distillation, but its oil must be checked and changed. A water jet pump is simple and cheap to buy, as with the water jet pump, PP, but uses a lot of water and its vacuum depends on water pressure. Compare the ultimate vacuum on each product page. Questions? Ask sales@luminixhealth.com.

Which ultimate vacuum and pumping speed do I need?

The ultimate vacuum, in mbar, is the lowest pressure a pump reaches; the pumping speed, in l/min or m³/h, is how fast it gets there. Filtration needs only a moderate vacuum, while drying, distilling high-boiling solvents and freeze-drying need a deeper one. Larger volumes, such as a big desiccator or a long tubing line, need more pumping speed to reach the target in reasonable time. Compare both values on the product page with what your method or instrument manual requires. Controllers, traps and hoses are in vacuum and pump accessories. Send us your application: sales@luminixhealth.com.

Do I need a chemically resistant pump?

Yes, when you pump aggressive vapours, such as acids, chlorinated solvents or other corrosive gases, for example from a rotary evaporator or a vacuum oven. Chemically resistant pumps have the parts that touch the gas, such as diaphragm, valves and head, made of PTFE, PVDF or similar materials; the product page lists the wetted materials, as with the double diaphragm pump, PP, PTFE. Even with a resistant pump, a cold trap before the inlet condenses vapours, protects the pump and keeps solvents out of the air. Traps are in vacuum and pump accessories. Questions? Ask sales@luminixhealth.com.

Which accessories do I need: cold trap, vacuum controller and tubing?

A cold trap condenses solvent vapours before they reach the pump, which protects the pump and keeps solvents out of the lab air and exhaust. A vacuum controller sets and holds a defined pressure, so evaporation and drying run reproducibly and solvents do not bump. Vacuum tubing must have thick enough walls not to collapse and an inner diameter that fits the hose barbs; too narrow a tube slows pumping down. Traps and controllers are in vacuum and pump accessories; hoses in tubing, hoses and fittings. Send us your set-up and we will complete the list: sales@luminixhealth.com.

Why Vacuum pumps?

A laboratory vacuum pump lowers pressure for filtration or evaporation. A diaphragm pump tolerates solvent vapour better than an oil-sealed rotary vane pump, and it reaches a milder vacuum. The ultimate vacuum and the flow, and whether the wetted path survives the solvent, are the choices.

A vacuum pump lowers the pressure above a liquid so it boils at a lower temperature. That is the point of a rotary evaporator: solvent leaves a sample without cooking it. A diaphragm pump or a rotary-vane pump is chosen by the vacuum it reaches and by whether solvent vapour will destroy it. A peristaltic pump moves liquid by squeezing a tube, so the liquid touches only the tube. A barrel pump transfers a larger volume from a drum. The glassware on the evaporator is indexed under ISO laboratory glassware. Solvent identity is on PubChem.

This shelf belongs to Pumps, vacuum & evaporation, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU, usually within 2 to 5 working days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?