Description
Density hydrometer 1,100–1,200:0,001 g/cm³ measures liquid density across the interval 1,100 to 1,200 g/cm³ at a scale division of 0,001 g/cm³. With an overall length of 300 mm and calibration referenced to 20 °C, the instrument supports repeatable density determination under standard laboratory temperature conditions. It is supplied without a thermometer and uses bottom reading of the scale. Manufactured in simple quality, this hydrometer is intended for everyday density work on liquids that fall within the higher portion of the common aqueous and process-fluid range. The clear 0,001 g/cm³ graduation allows direct numerical readout once the instrument floats freely in a suitable cylinder. Offered as a single piece from manufacturer Amarell, it complements series instruments covering adjacent density windows and is appropriate for quality control, educational use and routine process checks where an integrated temperature sensor is not required. Length, reference temperature and scale limits are fully defined so the hydrometer can be selected and applied with confidence for samples between 1,100 and 1,200 g/cm³.
This article is part of Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc
- Length: 300 mm
- Measuring range: 1,100–1,200 g/cm³
- Scale division: 0,001 g/cm³
- Reference temperature: 20 °C
- Thermometer: without
Recently viewed
You may also like
Questions about Density hydrometer, 1,100-1,200:0,001g/cm³, 300mm long, reference temperature
What is this article?
Density hydrometer, 1,100-1,200:0,001g/cm³, 300mm long, reference temperature is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.