Density hydrometer, type 3, 0,820-0,880:0,001g/cm³, 160mm long, reference

Catalog nr. H800008
Amarell

Price:
Sale price€24,20
Ask quote for bulk order

Description

Density hydrometer type 3 for the range 0,820–0,880 g/cm³ with a scale division of 0,001 g/cm³ is a laboratory instrument for determining the density of liquids. The unit is 160 mm long, referenced to 20 °C, supplied without a thermometer, and configured for bottom reading so the scale remains easy to observe during immersion. This type 3 density hydrometer from manufacturer Amarell is aimed at work within a defined mid-range density window where fine graduation supports accurate visual readout. The scale runs from 0,820 g/cm³ to 0,880 g/cm³, making it suitable for liquids that fall inside this interval. Provided as a single piece, it integrates into quality control, process monitoring, and analytical procedures that call for a short, thermometer-free hydrometer with a stated reference temperature. Straightforward construction simplifies handling, while the 0,001 g/cm³ division allows detailed observation of density values under standard laboratory practice. Users needing a compact type 3 instrument matched to these scale limits and reading arrangement can apply it directly in routine density checks.

This article is part of Hydrometers, in Density & viscosity measurement.

Key features

  • Pack size: 1 pc
  • Type: 3
  • Measuring range: 0,820–0,880 g/cm³
  • Scale division: 0,001 g/cm³
  • Length: 160 mm
  • Reference temperature: 20 °C

Recently viewed

You may also like

Questions about Density hydrometer, type 3, 0,820-0,880:0,001g/cm³, 160mm long, reference

What is this article?

Density hydrometer, type 3, 0,820-0,880:0,001g/cm³, 160mm long, reference is the article on this page. Luminix Health distributes Amarell for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.

A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.

Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.

Which category should I open next?

The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.

Shelves beside this one are Viscometers and Density meters & pycnometers.

What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Delivery across Europe, two to five days when in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?