Density hydrometer, without thermometer, measuring range 0.700 - 0.800 g/cm³

Catalog nr. HH88.1
Carl Roth

Volume: 1 pc(s)
Value Packs: 1 piece
Price:
Sale price€16,90
Ask quote for bulk order

Description

Density hydrometer without thermometer is a laboratory measuring instrument for determining liquid density across 0,700–0,800 g/cm³. This model is supplied without an integrated thermometer, enabling density work alongside separate temperature measurement when required by the method. It forms part of the density labware and measuring-instrument range and is intended for routine density checks in that specific gravity window. Provided as 1 pc from manufacturer ROTH SELECTION, the hydrometer weighs 0,050 kg and is practical for bench use and storage. The clearly defined 0,700–0,800 g/cm³ measuring range supports correct instrument selection for samples expected in this interval. Without combined thermometry, the device remains dedicated to density scale reading. Laboratories in research, quality control, and education that need a straightforward hydrometer for the stated g/cm³ span will find this configuration aligned with standard density-measurement workflows.

This article belongs on Hydrometers, in Density & viscosity measurement.

Key features

  • Pack size: 1 pc
  • Type: Density hydrometer
  • Measuring range: 0,700–0,800 g/cm³
  • Thermometer: Without thermometer
  • Weight: 0,050 kg

Recently viewed

You may also like

Questions about Density hydrometer, without thermometer, measuring range 0.700 - 0.800 g/cm³

What is this article?

Density hydrometer, without thermometer, measuring range 0.700 - 0.800 g/cm³ is the article on this page. Luminix Health distributes Carl Roth for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.

A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.

Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.

Which category should I open next?

The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.

Shelves beside this one are Viscometers and Density meters & pycnometers.

What should I check before I order?

The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?