Description
Density hydrometer without thermometer is a laboratory measuring instrument for determining liquid density in the range 1,700–1,800 g/cm³. It belongs to the density measuring instruments group within labware and supports direct density readings where a dedicated hydrometer scale is required. The unit is supplied without an integrated thermometer, so density determination remains the sole measurement function and temperature can be recorded separately when needed. Pack size is 1 pc(s), with a weight of 0,055 kg, making the instrument practical for routine bench work and storage alongside other density apparatus. Typical use includes density checks on liquids in analytical, process, and quality-related laboratory settings that call for the 1,700–1,800 g/cm³ interval. Offered from manufacturer ROTH SELECTION, this hydrometer fits standard density-measurement workflows in research and industrial laboratories. Clear scale coverage of the stated range helps operators select the correct instrument for samples expected in this density window. Combine with appropriate cylinders and handling practice for consistent comparative density assessment across batches and methods.
This article belongs on Hydrometers, in Density & viscosity measurement.
Key features
- Pack size: 1 pc(s)
- Type: Density hydrometer
- Thermometer: Without thermometer
- Measuring range: 1,700–1,800 g/cm³
- Weight: 0,055 kg
Recently viewed
You may also like
Questions about Density hydrometer, without thermometer, measuring range 1.700 - 1.800 g/cm³
What is this article?
Density hydrometer, without thermometer, measuring range 1.700 - 1.800 g/cm³ is the article on this page. Luminix Health distributes Carl Roth for laboratory use. It sits in Hydrometers, inside Density & viscosity measurement, in Lab instruments.
A hydrometer floats in a liquid and the stem reading is the density or a related scale such as Brix. The liquid has to be at the temperature printed on the stem, or a correction is required. A chip on the stem changes the reading. One hydrometer does not cover every density.
Density is mass divided by volume. A hydrometer floats at a depth that depends on the density of the liquid. A pycnometer is a vessel of known volume that is weighed full. Viscosity is the resistance to flow. A capillary viscometer times how long a volume takes to fall through a tube. Both measurements need a stated temperature, because liquids change density and viscosity as they warm. The units trace to the BIPM and to NIST.
Which category should I open next?
The category is Density & viscosity measurement. The sub-category is Hydrometers. The catalogue is Lab instruments.
Shelves beside this one are Viscometers and Density meters & pycnometers.
What should I check before I order?
The technical information on this page is the manufacturer's sheet. Read that, not a rewritten specification.
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.