L 1 BNC, Plug cable combination, coaxial electrode plug, 1 m coaxial cable, BNC

Catalog nr. 285122497
SI Analytics - a Xylem brand

Price:
Sale price€67,00
Ask quote for bulk order

Description

L 1 BNC is a plug-cable combination consisting of a coaxial electrode plug, a 1 m coaxial cable and a BNC device plug. This laboratory accessory provides a complete connection solution for electrode systems using BNC interfaces. The 1 m coaxial cable links the coaxial electrode plug to the BNC device plug for instrument interfacing. Supplied in a pack size of 1 pc, it features a net weight of 0,045 kg and identical gross weight. From manufacturer SI Analytics - a Xylem brand, the L 1 BNC is produced in Germany for professional laboratory use. The design incorporates a coaxial electrode plug at one end and a BNC device plug at the other. This configuration supports straightforward integration into existing measurement setups. With its compact form and defined cable length, the combination facilitates organized cabling in analytical workspaces. The product falls under other laboratory materials and offers a practical option for electrode connectivity needs. The robust construction ensures durability during regular handling in the lab environment.

This article is part of pH electrodes & sensors, in pH & electrochemistry.

Key features

  • Pack size: 1 pc
  • Product type: Plug-cable combination
  • Cable length: 1 m
  • Electrode connector: Coaxial electrode plug
  • Instrument connector: BNC device plug
  • EAN: 4064664024624
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about L 1 BNC, Plug cable combination, coaxial electrode plug, 1 m coaxial cable, BNC

What is this article?

L 1 BNC, Plug cable combination, coaxial electrode plug, 1 m coaxial cable, BNC is the article on this page. Luminix Health distributes SI Analytics - a Xylem brand for laboratory use. It sits in pH electrodes & sensors, inside pH & electrochemistry, in Lab instruments.

A pH electrode is a glass membrane and a reference. It is a consumable: the glass ages, the junction clogs, and the reading drifts. A refillable electrode and a gel electrode differ in how they are maintained. The connector has to match the meter. The electrode, not the meter, is usually what is wrong.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Delivery across Europe, two to five days when in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.