Description
Lid for AT-QL rotor 30x2 ml is an aerosol-tight aluminium rotor lid designed for the FA-45-30-11 rotor on Centrifuge 5430 and 5430 R. It covers 30-place AT-QL rotors configured for 2 ml tubes, helping maintain containment when centrifuging samples that require an aerosol-tight barrier. QuickLock closure allows rapid handling while supporting a secure seal once the lid is properly engaged with the rotor. The aluminium body offers a robust, stable fit for repeated laboratory use. The product is supplied as a single piece with a net weight of 0,207 kg, a gross weight of 0,230 kg and a packaging volume of 0,002 m³. From manufacturer Eppendorf, this lid is a dedicated accessory for users of the FA-45-30-11 AT-QL rotor on 5430 series centrifuges. It is suitable for molecular biology, clinical diagnostics and research laboratories that keep spare aerosol-tight rotor lids on hand to sustain safe, uninterrupted centrifugation workflows with 2 ml formats.
This article is part of Rotors, in Centrifuges.
Key features
- Pack size: 1 pc
- Material: Aluminium
- Compatible rotor: FA-45-30-11
- Capacity format: 30 × 2 ml
- Closure: QuickLock
- Seal: Aerosol-tight
Recently viewed
You may also like
Browse related categories
Category
Sub-category
Catalogue
Brand
Questions about LID F/30x2ML A-T QL ROTOR (5430)
What is this article?
LID F/30x2ML A-T QL ROTOR (5430) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.
A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.
A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.
Which category should I open next?
The category is Centrifuges. The sub-category is Rotors. The catalogue is Lab instruments.
Shelves beside this one are Rotor adapters & accessories, Benchtop & floor-standing centrifuges, Microcentrifuges & mini centrifuges and Centrifuge accessories.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

