Rotor 4 for VISC-2M0-001

Catalog nr. VISCA04001
Labbox

Price:
Sale price€11,00
Ask quote for bulk order

Description

Rotor 4 for VISC-2M0-001 is a dedicated measuring rotor intended for use with the VISC-2M0-001 laboratory viscometer. It supports rotational viscosity determination on Newtonian liquids within the instrument’s working concept, which covers a broad measuring range from 1 mPa·s (0,1 mPa·s with Rotor 0) up to 2.000.000 mPa·s at an accuracy of ±5 % for Newtonian fluids. The associated drive offers selectable speeds of 0,3 / 0,6 / 1,5 / 3 / 6 / 12 / 30 / 60 min⁻¹, enabling stepwise adjustment of shear conditions during routine quality control and method development. This rotor belongs to the four-rotor configuration of the VISC-2M0-001 system (a five-rotor variant is available as VISC-2M1-001) and is supplied as a single piece for straightforward exchange or replacement in daily laboratory work. The complete measuring setup from manufacturer Labbox also provides for an integrated temperature sensor and is specified with instrument dimensions of 370 × 325 × 280 mm and mains supply 110–230 V / 50–60 Hz. Rotor 4 is suited to laboratories that need a defined spindle option for METRIA viscosity instrumentation without altering the base measuring principle of the host device.

This article is part of Rotors, in Centrifuges.

Key features

  • Pack size: 1 pc
  • Product type: Measuring rotor
  • Compatibility: VISC-2M0-001 viscometer
  • EAN: 8434868115064
  • GTIN: 08434868115064
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about Rotor 4 for VISC-2M0-001

What is this article?

Rotor 4 for VISC-2M0-001 is the article on this page. Luminix Health distributes Labbox for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Delivery across Europe, two to five days when in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?