ROTOR 48x2ML WITH AT QL LID (5427R)

Catalog nr. 5409710001
Eppendorf

Price:
Sale price€840,00
Ask quote for bulk order

Description

Rotor 48 × 2 ml with AT-QL lid (5427 R) is the fixed-angle rotor FA-45-48-11 supplied complete with an aerosol-tight Eppendorf QuickLock® lid for the Centrifuge 5427 R. It holds up to 48 × 1,5/2,0 ml vessels and reaches a maximum relative centrifugal force of 18 213 × g at 12 700 rpm, supporting demanding microcentrifugation protocols. The aerosol-tight design with QuickLock® closure enables rapid, secure sealing for work with potentially hazardous or sensitive samples. This high-capacity rotor is intended for Centrifuge 5427 R systems and is supplied as a complete assembly including the matching lid. With a net weight of 2,250 kg and gross weight of 2,500 kg, the unit arrives ready for installation. Laboratories performing molecular biology, clinical diagnostics or high-throughput sample preparation benefit from the combination of capacity, speed and aerosol containment offered by this rotor from manufacturer Eppendorf. The packaging volume of 0,010 m³ reflects a robust, complete rotor package suited to busy core facilities and research laboratories that rely on the 5427 R platform.

This article is part of Rotors, in Centrifuges.

Key features

  • Pack size: 1 piece
  • Rotor type: FA-45-48-11 fixed-angle
  • Max. capacity: 48 × 1.5/2 ml vessels
  • Max. RCF: 18 213 × g (12 700 rpm)
  • Lid: Aerosol-tight Eppendorf QuickLock®
  • Compatible centrifuge: Centrifuge 5427 R
  • Manufacturer: Eppendorf
  • UNSPSC: 41103909
  • Maximum RCF: 18213 × g
  • Maximum speed: 12700 rpm
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about ROTOR 48x2ML WITH AT QL LID (5427R)

What is this article?

ROTOR 48x2ML WITH AT QL LID (5427R) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?