Rotor lid (F34-6-38)

Catalog nr. 5804727509
Eppendorf

Price:
Sale price€205,33
Ask quote for bulk order

Description

Rotor lid assembled (F-34-6-38) is a dedicated replacement lid for the F-34-6-38 fixed-angle rotor used on Eppendorf Centrifuge 58xx series instruments. It restores proper closure of the rotor chamber so that the F-34-6-38 can continue to be operated safely with its intended vessel formats. The assembled lid is supplied as a single piece ready for mounting, matching the geometry of the original rotor design. Suitable as a spare or service part when the existing cover requires replacement after wear or autoclaving cycles. This accessory from manufacturer Eppendorf maintains compatibility with the F-34-6-38 rotor on Centrifuge 5804, 5804 R, 5810 and 5810 R platforms. Pack size is 1 pc, allowing straightforward inventory of critical centrifuge consumables and spare parts in molecular-biology and general laboratory environments.

This article belongs on Rotors, in Centrifuges.

Key features

  • Pack size: 1 pc
  • Product type: assembled rotor lid
  • Compatible rotor: F-34-6-38
  • Centrifuge series: 58xx

Recently viewed

You may also like

Questions about Rotor lid (F34-6-38)

What is this article?

Rotor lid (F34-6-38) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?