SCP 930 Plus, IDS electrode with glass shaft, temp. sensor NTC 30 kOhm, 3 m

Catalog nr. 285101310
SI Analytics - a Xylem brand

Price:
Sale price€604,00
Ask quote for bulk order

Description

SCP 930 Plus is an IDS pH electrode with glass shaft, integrated NTC 30 kOhm temperature sensor and 3 m fixed cable ending in a digital plug. It features a platinum diaphragm, KCl 3 mol/l electrolyte and a Silamid® reference system with silver-ion barrier and double electrolyte, paired with a spherical membrane of A-glass. The electrode measures 170 mm in length and 12 mm in diameter, covering 0 to 14 pH at operating temperatures from –5 to +100 °C. Supplied as one piece from manufacturer SI Analytics – a Xylem brand, the digital IDS interface transmits calibrated data directly to compatible meters, reducing analogue interference. The platinum junction and double-electrolyte reference promote stable potentials in demanding aqueous matrices, while the extended temperature ceiling supports warmer process or laboratory samples. The 3 m cable length offers flexible placement of the meter relative to the measurement point. This configuration is intended for digital pH systems requiring a robust glass body, integrated temperature compensation and a defined high-temperature operating range.

This article is part of pH electrodes & sensors, in pH & electrochemistry.

Key features

  • Pack size: 1 pc
  • Product type: SCP 930 Plus
  • Connection: 3 m fixed cable with digital plug
  • Temperature sensor: NTC 30 kOhm
  • Diaphragm: Platinum
  • EAN: 4064664021425
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about SCP 930 Plus, IDS electrode with glass shaft, temp. sensor NTC 30 kOhm, 3 m

What is this article?

SCP 930 Plus, IDS electrode with glass shaft, temp. sensor NTC 30 kOhm, 3 m is the article on this page. Luminix Health distributes SI Analytics - a Xylem brand for laboratory use. It sits in pH electrodes & sensors, inside pH & electrochemistry, in Lab instruments.

A pH electrode is a glass membrane and a reference. It is a consumable: the glass ages, the junction clogs, and the reading drifts. A refillable electrode and a gel electrode differ in how they are maintained. The connector has to match the meter. The electrode, not the meter, is usually what is wrong.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Delivery across Europe, two to five days when in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?