Digital thermometers

Here you will find everything your laboratory needs for digital thermometers, such as: electronic digital therm, digital thermometer, term measuring points and TLC. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 165 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

165 products

Showing 1 - 24 of 165 products

Showing 1 - 24 of 165 products
View
MiniTherm standard immersion thermometer, measuring range −50 to +150 °C, Ø 4 mm, Bürkle, art. 53840011Bürkle
MiniTherm waterproof immersion thermometer, measuring range −20 to +230 °C, Bürkle, art. 53840012Bürkle
Digital maximum-minimum thermometer, black, Hecht, art. 43653020Hecht
Digital maximum-minimum thermometer, green, Hecht, art. 43653010Hecht
Thermometer with probe, digital, foldable, KT-600, 1 piece, Labbox, art. THERD33001Labbox
Digital thermometer with probe, straight form, -50 +300 °C, Labbox, art. THERD30001Labbox
Digital thermometer "ThermoJack" with foldable insertion probe, Hecht, art. 43238010Hecht
Wireless temperature gauge, type ETS-D7, IKA, art. 2AU4.1IKA
ETS-D5 contact thermometer, measuring range -20 to +400 °C, IKA, art. 28U0.1IKA

Recently viewed

Questions about Digital thermometers

Penetration probe, surface probe or wireless sensor: which do I need?

Choose by what you measure. A penetration probe goes into liquids and semi-solids, such as media, gels or food samples, like the digital thermometer with stainless steel piercing probe. A surface probe has a flat tip for hot plates, heating blocks and other surfaces. A wireless sensor sits in a fridge, freezer or incubator and sends readings without opening the door, such as the wireless temperature gauge. For continuous records, see data loggers. Separate probes are in temperature probes and sensors. Questions? Ask sales@luminixhealth.com.

Which resolution and measuring range do I need?

Resolution is the smallest step the display shows, such as 0.1 or 0.01 °C; it is not the same as accuracy, which tells you how close the reading is to the true temperature. A display with 0.01 °C can still be less accurate than one with 0.1 °C, so read the accuracy on the product page. Then check that the measuring range covers your coldest and warmest application with some margin, as with the multi-channel thermometer with 0.1 °C resolution. Unsure which specification your procedure requires? Ask sales@luminixhealth.com.

Do I need a calibration certificate?

You need one when your quality system, an audit or a customer asks for traceable temperature measurements, for example for fridges, incubators or stability storage. A calibration certificate documents the deviation of the thermometer at defined points. Some thermometers are sold with a certificate, which the product page states; for others, you can order calibration separately in calibration service and certificates. Plan recalibration at the interval your quality system sets. For routine checks without audit requirements, a thermometer without certificate is usually enough. Not sure what your audit requires? Ask sales@luminixhealth.com.

Digital thermometer or glass laboratory thermometer?

A digital thermometer reads quickly and clearly, and many models store minimum and maximum values or measure several channels at once, such as the electronic max/min thermometer with bar chart. Probes can be replaced and readings logged. A glass thermometer needs no battery, has no electronics to fail and is simple to check against a reference, which is why many labs keep one for baths and ovens; see laboratory glass thermometers. Choose glass for simple fixed points and digital for logging, alarms or several points. Questions? Ask sales@luminixhealth.com.

Why Digital thermometers?

A digital thermometer is a display plus a sensor. The resolution on the screen can be finer than the accuracy. The stated accuracy and the calibration point are what the number is worth. The probe type has to be the one the meter expects.

A thermometer reports a temperature. A liquid-in-glass thermometer is a calibrated column. A digital thermometer is a sensor and a display, and the sensor, not the display, is what is calibrated. An infrared thermometer reads a surface and depends on emissivity. A data logger stores the reading over time. Without a stated uncertainty and a calibration point, the number is only an indication. The scale is maintained by the BIPM and compared by EURAMET. Accreditation is BELAC.

This shelf belongs to Temperature measurement, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?