Buy Ultrafiltration & concentrators online
The Ultrafiltration & concentrators shelf sits in Filtration. Luminix Health supplies this range from a catalogue of 150.000 laboratory articles for hospitals, universities, pharma and industrial laboratories.
Browse our Ultrafiltration & concentrators
Ultrafiltration & concentrators
Filter paperSintered glass filter plates & discsSyringe filtersFilter cartridges & capsulesMembrane filtersGlass & quartz fibre filtersBottle-top & vacuum filtration unitsFiltration accessoriesExtraction thimblesDialysis tubing & devices
Filtration
Main catalogues
LabwareInstrumentsChemicalsConsumablesChromatographyLife Science & MicrobiologySafety
Not sure which article fits the bench? Tell us the application and the pack size. Our specialists help you find it, including a personal quote for the order.
Our brands of Ultrafiltration & concentrators
Luminix Health, your European distributor for Ultrafiltration & concentrators
Order Ultrafiltration & concentrators from Luminix Health and count on:
- ✓Personal contact and professional advice
- ✓Fast answers and shipping from the heart of Europe, delivery across the EU, two to five days if in stock
- ✓Competitive prices and a 24/7 online range
- ✓A complete assortment of laboratory equipment and supplies
Get in touch for a quote tailored to your laboratory's needs.
Recently viewed
Questions about Ultrafiltration & concentrators
Which MWCO (molecular weight cut-off) should I choose for my protein?
A common rule of thumb: choose an MWCO two to three times smaller than the molecular weight of the molecule you want to retain. A lower MWCO gives higher recovery but slower filtration. Check the MWCO in kDa on the product page. Many devices contain glycerine to protect the membrane; rinse before first use as the instructions describe. For buffer exchange in larger volumes, compare with dialysis tubing and devices. For a quote or a second opinion, write to sales@luminixhealth.com.
Which membrane material: PES, regenerated cellulose or CTA?
PES offers fast flux, low protein binding and a wide pH range, which makes it a common default. Regenerated cellulose has very low binding and good resistance to many solvents. CTA, cellulose triacetate, also binds little and is intended for aqueous solutions. If recovery of a scarce protein matters most, compare binding data on the product pages in ultrafiltration and concentrators. Questions about a specific product? Contact sales@luminixhealth.com.
Centrifugal concentrator, stirred cell or tangential flow: which suits my volume?
Centrifugal concentrators handle microlitres up to small volumes in an ordinary centrifuge, with a suitable rotor. A stirred cell with a flat membrane handles tens to hundreds of millilitres under gas pressure. Tangential or crossflow cassettes handle litres and need a pump. Choose by volume and how often you run it. Stirred cells need a gas supply, usually nitrogen, to apply the pressure. See rotors and peristaltic and dosing pumps. Unsure which one fits? Ask sales@luminixhealth.com.
What is the difference between concentrating and diafiltration?
Concentrating reduces the volume: solvent and small molecules pass through the membrane while your target molecule stays behind. Diafiltration adds fresh buffer during concentration to wash out salts or small molecules, which amounts to a buffer exchange. It is a faster alternative to dialysis for many samples. Both steps can run in one device. For the classic route, see dialysis tubing and devices. Need advice for your set-up? Mail sales@luminixhealth.com.
Why Ultrafiltration & concentrators?
An ultrafiltration device holds back macromolecules above a stated molecular-weight cutoff and passes salts and water. It concentrates a protein or exchanges its buffer. The cutoff, the volume and whether it is a centrifugal device or a stirred cell are the specification. A 0.2 µm syringe filter does not do this.
Filtration holds back what is larger than the pores and lets the rest through. Paper is the ordinary laboratory filter. A membrane has a stated pore size and a polymer that must survive the solvent. A syringe filter is that membrane in a housing on a syringe. Glass fibre takes a higher dirt load. Ultrafiltration holds back macromolecules and passes salts. The pore size, the chemical compatibility and the volume are the three choices. Laboratory apparatus around filtration is indexed under ISO laboratory apparatus.
This shelf belongs to Filtration, inside Lab consumables. Luminix Health distributes this range for laboratory use.
Which shelves sit beside this one?
The neighbouring shelves are Filter paper, Sintered glass filter plates & discs, Syringe filters, Filter cartridges & capsules, Membrane filters, Glass & quartz fibre filters, Bottle-top & vacuum filtration units, Filtration accessories, Extraction thimbles and Dialysis tubing & devices. The category above this shelf is Filtration.
How does ordering and shipping work?
Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology. If the article is not on the shelf, request a quote.