Description
Dynamic climate chamber MK720-480V-C enables heat and cold testing over a temperature range from -40 °C to +180 °C. Its nominal volume of 734 l makes it suitable for larger sample loads and cyclic temperature programmes as a flexible alternative to elaborate custom systems. APT.line™ preheating chamber technology supports uniform temperature distribution, complemented by programmable condensation protection for the specimens. A heated viewing window with LED interior lighting, door heating and a stainless steel interior with one stainless steel shelf aid routine operation. The intuitive touchscreen controller provides time-segment and real-time programming, adjustable ramp function, integrated line recorder and real-time clock. Measured values are stored by an internal data logger and can be read out in open format via USB; Ethernet serves as the computer interface. Two 80 mm access ports with silicone plugs are fitted on the left and right. Further equipment includes a class 2 temperature selector limiter to DIN 12880 with optical alarm, fault diagnosis with optical and acoustic alarm, four castors (two with locking brakes) and CFC-free refrigerant R-452A with compression refrigeration. APT-COM™ Basic Edition software is supplied. This MK series unit from manufacturer Binder is designed for demanding thermal cycling applications.
This article is part of Drying ovens & climate chambers, in Heating, drying & cooling.
Key features
- Pack size: 1 pc
- Temperature range: -40 °C to +180 °C
- Nominal volume: 734 l
- Controller: intuitive touchscreen with time-segment and real-time programming
- Access ports: 2 × 80 mm with silicone plugs (left and right)
- Safety: temperature selector limiter class 2 (DIN 12880)
- Manufacturer: Binder
- UNSPSC: 41104900
- Interior dimensions: 1200 × 600 × 1020 mm (W × D × H)
- Exterior dimensions: 1580 × 1140 × 2005 mm (W × D × H)
- Weight, empty: 570 kg
- Voltage: 480 V, 60 Hz
- Nominal power: 8.7 kW
- Temperature uniformity, depending on setpoint: ±0.3...±2 K
- Temperature fluctuation, depending on setpoint: ±0.1...±0.5 K
- Average heating-up rate between -40 °C and 180 °C: 4 K/min
- Cooling-down time from 180 °C to -40 °C: 100 min
- Average cooling-down time between 180 °C and -40 °C: 4.5 K/min
- Shelves, standard / maximum: 1/11
- Load per rack: 40 kg
- Permitted load: 160 kg
- Energy consumption at 20 °C: 1900 Wh/h
- Wall clearance, side: 200 mm
- Wall clearance, back: 300 mm
- Sound pressure level: 67 dB(A)
- Technical Information Sheet:
- Data Sheet:
Recently viewed
You may also like
Questions about Dynamic climate chambers MK720-480V-C
What is this article?
Dynamic climate chambers MK720-480V-C is the article on this page. Luminix Health distributes Binder for laboratory use. It sits in Drying ovens & climate chambers, inside Heating, drying & cooling, in Lab instruments.
A drying oven holds a temperature above ambient to drive off water or to condition a sample. A climate chamber also holds humidity. Uniformity across the chamber, not only the set point, decides whether two samples on different shelves saw the same conditions.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Drying ovens & climate chambers. The catalogue is Lab instruments.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Water & oil baths, Hot plates & heating blocks, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Autoclaves & sterilisers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.