Description
Dynamic climate chamber MKF 56-230V is an environmental simulation cabinet for combined temperature and humidity testing according to common DIN and IEC climate standards. It covers −40 °C to +180 °C and a humidity range of 10 % r.H. to 98 % r.H. in a 60 l stainless-steel interior, making it suitable for cold, heat and climatic stress programmes. Humidity is controlled via a capacitive humidity sensor with steam humidification; APT.line™ preheating chamber technology and programmable condensation protection support stable, sample-friendly conditions. A heated viewing window with LED lighting, door heating and a Pt 100 temperature sensor are provided. The MCS controller activates four potential-free switching contacts and drives an intuitive touchscreen with time-segment and real-time programming, adjustable ramp function, integrated chart recorder and real-time clock. An internal data logger exports open-format data via USB; Ethernet connectivity and APT-COM™ Basic Edition software aid multi-unit management. Standard equipment includes one stainless-steel rack, 50 mm left-side access port with silicone plug, hose burst protection with water supply and drain up to 1 m height, four castors (two lockable), PUR foam insulation and compression cooling with CFC-free R-452A. This MKF unit from manufacturer Binder combines broad simulation capability with practical laboratory handling.
This article is part of Drying ovens & climate chambers, in Heating, drying & cooling.
Key features
- Pack size: 1 pc
- Nominal volume: 60 l
- Temperature range: −40 °C to +180 °C
- Humidity range: 10 % r.H. to 98 % r.H.
- Humidity control: Capacitive sensor with steam humidification
- Preheating technology: APT.line™
- Manufacturer: Binder
- UNSPSC: 41104900
- Interior dimensions: 400 × 348 × 420 mm (W × D × H)
- Exterior dimensions: 720 × 780 × 1445 mm (W × D × H)
- Weight, empty: 175 kg
- Voltage: 230 V, 50 Hz
- Nominal power: 2.8 kW
- Temperature range with humidity: 10...95 °C
- Temperature uniformity, depending on setpoint: ±0.5...±1.5 K
- Temperature fluctuation, depending on setpoint: ±0.1...±0.5 K
- Temperature fluctuation with humidity, depending on setpoint: ±0.1...±0.5 K
- Average heating-up rate between -40 °C and 180 °C: 5 K/min
- Cooling-down time from 180 °C to -40 °C: 90 min
- Average cooling-down time between 180 °C and -40 °C: 5 K/min
- Max. heat compensation at 25 °C and 90% RH: 250 W
- Shelves, standard / maximum: 1/4
- Load per rack: 15 kg
- Permitted load: 60 kg
- Energy consumption at 25 °C and 60% RH: 800 Wh/h
- Wall clearance, side: 200 mm
- Wall clearance, back: 300 mm
- Sound pressure level: 59 dB(A)
- Technical Information Sheet:
- Data Sheet:
Recently viewed
You may also like
Questions about Dynamic climate chambers MKF 56-230V
What is this article?
Dynamic climate chambers MKF 56-230V is the article on this page. Luminix Health distributes Binder for laboratory use. It sits in Drying ovens & climate chambers, inside Heating, drying & cooling, in Lab instruments.
A drying oven holds a temperature above ambient to drive off water or to condition a sample. A climate chamber also holds humidity. Uniformity across the chamber, not only the set point, decides whether two samples on different shelves saw the same conditions.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Drying ovens & climate chambers. The catalogue is Lab instruments.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Water & oil baths, Hot plates & heating blocks, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Autoclaves & sterilisers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.