Description
KBF 260 (E7) (120V) is a constant climate chamber from the KBF series, built for laboratory work that needs a wide temperature and humidity range. This standard model offers an interior volume of 262 L and is specified as KBF260UL-120V for operation on 120 V 1~ 50/60 Hz. The chamber supports controlled climate conditions for stability testing, sample conditioning, and related environmental protocols where reproducible temperature and humidity settings matter. With a net weight of 218 kg and a gross weight of 220 kg, the unit is a robust freestanding laboratory appliance intended for professional use. Available from manufacturer Binder as a complete standard configuration, the KBF 260 (E7) (120V) fits facilities that require reliable constant-climate performance in a mid-size chamber format. Pack size is one piece. Origin is Germany (Baden-Württemberg). The design focuses on a broad working envelope for temperature and humidity without additional specialised options beyond the standard KBF series specification.
This article is part of Drying ovens & climate chambers, in Heating, drying & cooling.
Key features
- Pack size: 1 pc(s)
- Product type: Constant climate chamber
- Series: KBF (standard)
- Interior volume: 262 L
- Electrical connection: 120 V 1~ 50/60 Hz
- Manufacturer: Binder
- Net weight: 218 kg
- UNSPSC: 41104900
- Interior dimensions: 656 × 575 × 695 mm (W × D × H)
- Exterior dimensions: 930 × 900 × 1396 mm (W × D × H)
- Weight, empty: 188 kg
- Voltage: 120 V, 50/60 Hz
- Nominal power: 1.4 kW
- Temperature range: 0...70 °C
- Temperature range with humidity: 10...70 °C
- Temperature uniformity at 25 °C and 60% RH: ±0.3 K
- Temperature uniformity at 40 °C and 75% RH: ±0.2 K
- Temperature fluctuation at 25 °C and 60% RH: ±0.1 K
- Temperature fluctuation at 40 °C and 75% RH: ±0.1 K
- Recovery time after a 30 s door opening at 25 °C and 60% RH: 2 min
- Recovery time after a 30 s door opening at 40 °C and 75% RH: 3 min
- Humidity range: 10...80 % RH
- Humidity fluctuation at 25 °C and 60% RH: ±1.5 % RH
- Humidity fluctuation at 40 °C and 75% RH: ±1.5 % RH
- Max. heat compensation at 40 °C: 410 W
- Inner doors: 1
- Shelves, standard / maximum: 2/9
- Load per rack: 40 kg
- Permitted load: 200 kg
- Energy consumption at 25 °C and 60% RH: 255 Wh/h
- Energy consumption at 40 °C and 75% RH: 295 Wh/h
- Wall clearance, side: 180 mm
- Wall clearance, back: 100 mm
- Sound pressure level at 25 °C and 60% RH: 50 dB(A)
- Data Sheet:
Recently viewed
You may also like
Questions about KBF 260 (E7) (120V)
What is this article?
KBF 260 (E7) (120V) is the article on this page. Luminix Health distributes Binder for laboratory use. It sits in Drying ovens & climate chambers, inside Heating, drying & cooling, in Lab instruments.
A drying oven holds a temperature above ambient to drive off water or to condition a sample. A climate chamber also holds humidity. Uniformity across the chamber, not only the set point, decides whether two samples on different shelves saw the same conditions.
Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.
Which category should I open next?
The category is Heating, drying & cooling. The sub-category is Drying ovens & climate chambers. The catalogue is Lab instruments.
Shelves beside this one are Muffle & tube furnaces, Heating mantles, Circulators, chillers & thermostats, Water & oil baths, Hot plates & heating blocks, Incubators, Heating & cooling (other), Temperature control accessories, Laboratory refrigerators & freezers, Autoclaves & sterilisers, Bunsen & gas burners and Heating tapes, cables & plates.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.