Description
ZF1HC is a 1/16'' ferrule in HC configuration for secure tubing connections in laboratory fluid-handling and chromatography systems. This precision fitting is intended to form a reliable mechanical seal on 1/16 inch lines where consistent joint integrity is required during instrument setup and maintenance. It is supplied as a single piece, matching the stated pack unit for straightforward stocking and replacement. Packaging data describe a compact item with a packaging volume of 0,000015 m³ and outer dimensions of 0,01 m height, 0,03 m width and 0,07 m depth. The article originates from the USA and is designated non-sterile, so it is aimed at general laboratory workflows rather than aseptic processes. Laboratories use such ferrules together with compatible nuts and tubing to establish leak-resistant joints in analytical fluid paths. The ZF1HC designation clearly identifies the 1/16'' HC format for ordering and inventory control. This ferrule from manufacturer Macherey-Nagel supports routine system assembly, service work and instrument configuration wherever a 1/16'' HC ferrule is specified.
This article is part of HPLC fittings, tubing & inline filters, in HPLC columns & accessories.
Key features
- Pack size: 1 pc
- Product type: Ferrule 1/16'', HC
- Tubing size: 1/16''
- Country of origin: USA
- Sterility: No
- Packaging volume: 0,000015 m³
Recently viewed
You may also like
Browse related categories
Category
Sub-category
HPLC fittings, tubing & inline filters
Catalogue
Brand
Questions about ZF1HC
What is this article?
ZF1HC is the article on this page. Luminix Health distributes Macherey-Nagel for laboratory use. It sits in HPLC fittings, tubing & inline filters, inside HPLC columns & accessories, in Chromatography equipment.
HPLC fittings and tubing are numbered by bore. A wide bore after the column broadens the peaks. Finger-tight and wrench fittings, and stainless against PEEK, are different pressure ratings. An inline filter is the last screen before the column, and it clogs on purpose so the column does not.
An HPLC column is a tube packed, or coated, with a stationary phase. The sample is carried through it by a liquid, and the compounds leave at different times. The phase, the particle size, the length and the internal diameter decide the separation. A guard column is a short sacrificial piece in front of the analytical column. Fittings and tubing have a bore that either preserves the peak or smears it. Compound names follow IUPAC. Data are on PubChem. Method grades often cite the European Pharmacopoeia or USP.
Which category should I open next?
The category is HPLC columns & accessories. The sub-category is HPLC fittings, tubing & inline filters. The catalogue is Chromatography equipment.
Shelves beside this one are HPLC columns, HPLC guard columns and HPLC accessories.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.

