Vacuum drying chambers VD023-230V

Catalog nr. 96300001
Binder

Price:
Sale price€7.825,00
Ask quote for bulk order

Accessories

Vacuum pump VP1, Binder, art. 50130256Binder
Binder Vacuum pump VP1
Sale price€3.354,53
Vacuum pump VP2, Binder, art. 50130257Binder
Binder Vacuum pump VP2
Sale price€5.663,04
Qualification documents, Binder, art. 70070001Binder
Binder Qualification documents
Sale price€1.318,52
Qualification documents IQ/OQ/PQ extension for temperature, CO2, O2 or pressure, Binder, art. 70070005Binder
Binder Qualification documents
Sale price€1.995,36
Qualification documents, Binder, art. 70570001Binder
Binder Qualification documents
Sale price€1.160,30
Qualification documents IQ/OQ/PQ extension, Binder, art. 70570005Binder
Binder Qualification documents
Sale price€1.756,93
Expansion racksBinder
Binder Expansion racks
Sale price€470,27
Clamping inserts, stainless steel, Binder, art. 80122259Binder
Binder Expansion racks
Sale price€528,51
Connection kit VD VP1-VP2, Binder, art. 80122613Binder
Binder Connection kit VD VP1-VP2
Sale price€293,37

Description

Vacuum drying oven VD023-230V is a BINDER VD-series unit for gentle vacuum drying with precise temperature control. The temperature range extends from +9 °C above ambient temperature up to +220 °C, supported by a controller with digital display of pressure and temperature. Program-controlled drying monitoring provides automatic ventilation at process end, while an internal data logger stores measured values that can be read out via USB in an open format. One individually positionable aluminium expansion rack uses patented expansion-rack technology for optimal heat transfer; the interior is easy to clean. Universal ventilation can be used with inert gas or ambient air, and a DN 16 port allows introduction of external measuring equipment. A spring-mounted safety glass pane with splinter protection and a large viewing window (optional interior lighting) support safe observation. Computer interface options include Ethernet; the unit also offers a USB interface. With a nominal volume of 24 l, 1400 W power consumption and 230 V AC supply (Euro plug type C), this oven from manufacturer Binder is suited to controlled vacuum drying in laboratory environments. Gross weight is 73 kg (net 71 kg).

This article is part of Muffle & tube furnaces, in Heating, drying & cooling.

Key features

  • Pack size: 1 pc
  • Nominal volume: 24 l
  • Temperature range: +9 °C above ambient to +220 °C
  • Power consumption: 1400 W
  • Supply voltage: 230 V AC
  • Controllable parameters: air pressure, vacuum
  • Technical Information Sheet: PDF

Accessories

Vacuum pump VP1, Binder, art. 50130256Binder
Binder Vacuum pump VP1
Sale price€3.354,53
Vacuum pump VP2, Binder, art. 50130257Binder
Binder Vacuum pump VP2
Sale price€5.663,04
Qualification documents, Binder, art. 70070001Binder
Binder Qualification documents
Sale price€1.318,52
Qualification documents IQ/OQ/PQ extension for temperature, CO2, O2 or pressure, Binder, art. 70070005Binder
Binder Qualification documents
Sale price€1.995,36
Qualification documents, Binder, art. 70570001Binder
Binder Qualification documents
Sale price€1.160,30
Qualification documents IQ/OQ/PQ extension, Binder, art. 70570005Binder
Binder Qualification documents
Sale price€1.756,93
Expansion racksBinder
Binder Expansion racks
Sale price€470,27
Clamping inserts, stainless steel, Binder, art. 80122259Binder
Binder Expansion racks
Sale price€528,51
Connection kit VD VP1-VP2, Binder, art. 80122613Binder
Binder Connection kit VD VP1-VP2
Sale price€293,37

Recently viewed

You may also like

Questions about Vacuum drying chambers VD023-230V

What is this article?

Vacuum drying chambers VD023-230V is the article on this page. Luminix Health distributes Binder for laboratory use. It sits in Muffle & tube furnaces, inside Heating, drying & cooling, in Lab instruments.

A muffle furnace surrounds a sample with heat for ashing or ignition, often to 1100 °C. A tube furnace heats a sample in a controlled atmosphere inside a tube. The maximum temperature and the chamber size are the specification. A drying oven is not a furnace.

Temperature equipment either holds a set point or drives a sample toward one. An oven dries. A furnace reaches the temperatures of ashing and melting. A bath surrounds a vessel with water or oil. A circulator moves that fluid. An incubator holds the mild warmth of a culture. An autoclave uses steam under pressure to sterilise. The number that matters is the temperature the article actually reaches, not the number painted on the dial. Temperature is part of the international system kept by the BIPM and compared by EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?