ROTOR 30x2ML COATED WITH LID (5430)

Catalog nr. 5427712003
Eppendorf

Price:
Sale price€534,00
Ask quote for bulk order

Description

Rotor F-45-30-11 is a PTFE-coated fixed-angle rotor supplied complete with lid for Centrifuge 5430 and 5430 R. It holds up to 30 × 1,5/2,0 ml microcentrifuge tubes and reaches a maximum speed of 14 000 rpm, corresponding to a relative centrifugal force of 20 817 × g. The PTFE coating improves chemical resistance, supporting work with aggressive reagents and solvents typical of molecular biology, biochemistry and analytical laboratories. From manufacturer Eppendorf, this single-piece rotor combines durable construction with a protective surface suited to demanding sample-preparation routines. Net weight is 1,170 kg. Fixed-angle geometry delivers consistent pelleting across all positions, while the included lid secures vessels during high-speed runs. The design integrates directly with the 5430 series, enabling efficient processing of standard microtube formats in research, diagnostics and quality-control settings. Laboratories that require reliable microtube centrifugation together with enhanced chemical durability will find this coated rotor a practical accessory for both routine and chemically challenging workflows.

This article is part of Rotors, in Centrifuges.

Key features

  • Pack size: 1 piece
  • Model: F-45-30-11
  • Capacity: 30 × 1.5/2 ml tubes
  • Max. RCF: 20817 × g
  • Max. speed: 14000 rpm
  • Coating: PTFE
  • Manufacturer: Eppendorf
  • UNSPSC: 41103909
  • Maximum RCF: 20817 × g
  • Maximum speed: 14000 rpm
  • Technical Information Sheet: PDF

Recently viewed

You may also like

Questions about ROTOR 30x2ML COATED WITH LID (5430)

What is this article?

ROTOR 30x2ML COATED WITH LID (5430) is the article on this page. Luminix Health distributes Eppendorf for laboratory use. It sits in Rotors, inside Centrifuges, in Lab instruments.

A centrifuge rotor is the rotating part that holds the tubes, and it is rated for a maximum speed and a maximum load. A swing-out rotor and a fixed-angle rotor pellet differently. A rotor from another centrifuge does not belong on this drive, even when it seems to fit.

A centrifuge separates by density. The rotor spins the sample and the force is reported as a multiple of gravity, not as a raw speed, because the same revolutions per minute are a different force at a different radius. A microcentrifuge takes small tubes. A benchtop or floor model takes larger rotors. The tube, the adapter and the rotor have to be the combination the manufacturer rated. An unbalanced load is how centrifuges fail. Measurement of the related quantities sits with the BIPM.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?