Description
6212 reference electrode is a double-junction Ag/AgCl reference half-cell specifically intended for use with the 7801 electrode. It incorporates a ceramic diaphragm and is filled with 0,1 M KCl together with 0,1 M CsCl electrolyte. The glass shaft measures 12 mm in diameter and 155 mm in length and is fitted with a 1 m cable whose terminations can be supplied as required. The double-junction architecture helps minimise contamination of the inner reference system when working with samples that may be incompatible with conventional single-junction fillings. Offered as a single-piece unit from manufacturer APERA Instruments, the 6212 provides a stable reference potential matched to the 7801 sensing electrode. Its glass construction and ceramic junction ensure reliable ionic continuity, while the dual electrolyte composition supports measurements where sample matrix effects must be reduced. The electrode is designed for laboratory potentiometric setups that specify a double Ag/AgCl reference paired with the 7801 sensor.
This article is part of Titrators & electrochemistry systems, in pH & electrochemistry.
Key features
- Pack size: 1 pc
- Product type: Reference electrode
- Reference system: Double, Ag/AgCl
- Diaphragm: Ceramic
- Electrolyte: 0,1 M KCl and 0,1 M CsCl
- Shaft material: Glass
Recently viewed
You may also like
Questions about 6212, reference electrode (for 7801)
What is this article?
6212, reference electrode (for 7801) is the article on this page. Luminix Health distributes APERA Instruments for laboratory use. It sits in Titrators & electrochemistry systems, inside pH & electrochemistry, in Lab instruments.
A titrator adds a reagent and watches an electrode until an endpoint, then calculates the amount. It is a burette, a stirrer and a meter in one. The electrode and the reagent concentration still decide the result. A manual titration is the same chemistry without the automation.
A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.
Which category should I open next?
The category is pH & electrochemistry. The sub-category is Titrators & electrochemistry systems. The catalogue is Lab instruments.
Shelves beside this one are pH electrodes & sensors, pH meters, Conductivity meters & cells, Dissolved oxygen & multiparameter meters and pH & electrochemistry accessories.
What should I check before I order?
When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.
How does ordering and shipping work?
We deliver across the EU, usually within 2 to 5 working days. More is on Delivery across the EU. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology.