Copper electrode outer, Cathode copper for e-Hive

Catalog nr. 0040007436
IKA

Price:
Sale price€1.241,85
Ask quote for bulk order

Description

Copper electrode outer is a copper cathode designed for the e-Hive screening platform. It constitutes the lower vial section of the electrode assembly and is paired with the rod, which is recommended as the anode, to form a complete electrochemical cell for screening applications. The active surface of the cathode reaches up to 700 mm², providing an extended interface for electrochemical experiments. Delivered as a single piece, this outer electrode from manufacturer IKA is intended for laboratories that require copper as the cathode material within the e-Hive workflow. Additional electrode materials can be requested to match specific experimental needs. The copper outer cathode supports researchers performing electrochemical screening on the e-Hive system, where a defined cathode geometry and larger active area contribute to consistent experimental conditions across multiple screening runs.

This article belongs on pH electrodes & sensors, in pH & electrochemistry.

Key features

  • Pack size: 1 pc
  • Storage temperature: 5–40 °C
  • Electrode type: Outer cathode (vial base)
  • Material: Copper
  • Active surface area: up to 700 mm²
  • EAN: 4053411051761

Recently viewed

You may also like

Questions about Copper electrode outer, Cathode copper for e-Hive

What is this article?

Copper electrode outer, Cathode copper for e-Hive is the article on this page. Luminix Health distributes IKA for laboratory use. It sits in pH electrodes & sensors, inside pH & electrochemistry, in Lab instruments.

A pH electrode is a glass membrane and a reference. It is a consumable: the glass ages, the junction clogs, and the reading drifts. A refillable electrode and a gel electrode differ in how they are maintained. The connector has to match the meter. The electrode, not the meter, is usually what is wrong.

A pH meter is a voltmeter on a glass electrode. The voltage tracks hydrogen-ion activity, and the electrode is converted to pH only after it is adjusted with buffers of known value. Conductivity measures how well a solution carries a current, which for dilute salts tracks concentration. Dissolved oxygen and titration are further electrodes on the same idea: a sensor, a standard, and a reading that is only as fresh as the calibration. Buffer values and chemical identity sit on PubChem. Accreditation of the calibration laboratory is the field of BELAC and EURAMET.

Which category should I open next?
What should I check before I order?

When this page shows a safety data sheet, use that manufacturer file. Hazard text does not belong in the sales description. For a pack size, a grade or a certificate that is not on the page, send a quote request or contact the team.

How does ordering and shipping work?

Luminix Health distributes this article from the heart of Europe. Articles in stock ship within 2–5 business days. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. The full brand index is on shop by brand. Who we are is on about us.

Which other categories should I open?