Buy Counting chambers & haemocytometers online
The Counting chambers & haemocytometers shelf sits in Microscopy & histology. Luminix Health supplies this range from a catalogue of 150.000 laboratory articles for hospitals, universities, pharma and industrial laboratories.
Browse our Counting chambers & haemocytometers
Counting chambers & haemocytometers
Microscope slides & cover glassesMicroscope objectives, eyepieces & opticsHistology cassettes & mouldsStereo microscopesLight & fluorescence microscopesHistology reagents & consumablesMicroscopy accessoriesCold light sources & lightingDigital & USB microscopes
Microscopy & histology
Main catalogues
LabwareInstrumentsChemicalsConsumablesChromatographyLife Science & MicrobiologySafety
Not sure which article fits the bench? Tell us the application and the pack size. Our specialists help you find it, including a personal quote for the order.
Our brands of Counting chambers & haemocytometers
Luminix Health, your European distributor for Counting chambers & haemocytometers
Order Counting chambers & haemocytometers from Luminix Health and count on:
- ✓Personal contact and professional advice
- ✓Fast answers and shipping from the heart of Europe, delivery across the EU, two to five days if in stock
- ✓Competitive prices and a 24/7 online range
- ✓A complete assortment of laboratory equipment and supplies
Get in touch for a quote tailored to your laboratory's needs.
Recently viewed
Questions about Counting chambers & haemocytometers
Neubauer, Bürker, Fuchs-Rosenthal or Nageotte?
Choose by how dense your sample is. For cell culture and blood cells, the Neubauer improved chamber and the Bürker chamber are the usual choices; both have a chamber depth of 0.1 mm. For samples with few cells, such as cerebrospinal fluid, a deeper chamber counts a larger volume: the Fuchs-Rosenthal chamber is 0.2 mm deep. The Nageotte chamber, at 0.5 mm, is meant for very low cell counts. Follow the chamber type your method or SOP names, so your calculation factor stays correct. Questions: sales@luminixhealth.com.
Bright-line or dark-line?
It is about how well you see the grid. On a bright-line chamber, the ruling stands out clearly against the background in brightfield, which makes counting less tiring, especially for longer series. A dark-line chamber shows the grid as dark lines; some users find it easier with certain stains or optics. Both types are available with the same ruling and depth, for example the Neubauer chamber with bright line and the Neubauer chamber with dark line, each with a V-groove for loading. If your microscope set-up is standard brightfield, bright-line is the common choice.
Glass or disposable?
A glass chamber lasts for years when you clean it carefully, and it is the reference in many SOPs. It suits labs that count regularly and want a fixed, traceable instrument. A disposable plastic chamber needs no cleaning and avoids carry-over between samples, which helps with infectious material or high throughput. The disposable Neubauer improved counting chamber comes in packs of 50 pieces. Many labs keep a glass chamber, such as the Neubauer improved chamber, as the reference and use disposables for routine counts.
Which cover glass?
A counting chamber needs its own cover glass. It is thicker and flatter than a standard microscope cover slip, so it sets the chamber depth correctly and does not bend over the ridges. Most chambers here, such as the Neubauer improved chamber, come with two cover glasses of 0.4 mm thickness. An ordinary thin cover slip gives a wrong volume and therefore a wrong count. For other microscopy work, standard cover slips and slides are in microscope slides and cover glasses. Spare ones are available too, such as the haemocytometer cover glass, 20 × 26 × 0.4 mm.
Why Counting chambers & haemocytometers?
A counting chamber is a slide with a ruled grid of known depth, so cells in a volume can be counted under a microscope. A haemocytometer is that chamber for blood or for cultured cells. The depth and the ruling are the specification. A scratched grid miscounts.
A light microscope forms an image with glass lenses and transmitted or reflected light. A stereo microscope is the lower-magnification instrument for dissecting and for looking at a surface. Fluorescence needs a light source and filters matched to the dye. Histology is the preparation that makes a tissue readable: fixation, a cassette, a section, a stain. The objective's magnification and numerical aperture decide the resolution. The slide and the cover glass decide whether the section sits in the focal plane. Stains and dyes as substances are identified on PubChem. Papers on the methods are on PubMed.
This shelf belongs to Microscopy & histology, inside Lab instruments. Luminix Health distributes this range for laboratory use.
Which shelves sit beside this one?
The neighbouring shelves are Microscope slides & cover glasses, Microscope objectives, eyepieces & optics, Histology cassettes & moulds, Stereo microscopes, Light & fluorescence microscopes, Histology reagents & consumables, Microscopy accessories, Cold light sources & lighting and Digital & USB microscopes. The category above this shelf is Microscopy & histology.
How does ordering and shipping work?
Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.
Which other categories should I open?
The seven catalogues are Labware, Lab chemicals, Lab instruments, Lab consumables, Chromatography equipment, Lab safety equipment and Life Science & Microbiology. If the article is not on the shelf, request a quote.