Mills, grinders & homogenisers

Here you will find everything your laboratory needs for mills, grinders and homogenisers. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 413 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

413 products

Showing 1 - 24 of 413 products

Showing 1 - 24 of 413 products
View
Funnel with slide valve Di=27 mm P-29, Fritsch, art. 29115100Fritsch
Rotor 24 ribs P-14 cl stainless steel, Fritsch, art. 44424010Fritsch
Rotor 12 ribs P-14 cl pure titanium with holding magnet, Fritsch, art. 44412032Fritsch
Rotor 24 ribs P-14 cl TiN-coated, Fritsch, art. 44424000Fritsch
Rotor 12 ribs P-14 cl TiN coated, Fritsch, art. 44412000Fritsch
Rotor 12 ribs P-14 cl stainless steel, Fritsch, art. 44412010Fritsch
Rotor 6 ribs, pure titanium P-14, Fritsch, art. 14443032Fritsch
Rotor 24 ribs, pure titanium P-14, Fritsch, art. 14443732Fritsch
Rotor 8 ribs P-14 cl stainless steel, Fritsch, art. 44408010Fritsch
Rotor 12 ribs, stainless steel 316L, P-14, Fritsch, art. 14433510Fritsch
Rotor 12 ribs, pure titanium P-14, Fritsch, art. 14443432Fritsch
24-rib impact rotor P-14 stainless steel, Fritsch, art. 14433710Fritsch
Rotor 6 ribs P-14 stainless steel, Fritsch, art. 14433010Fritsch
Rotor 12 ribs P-14 stainless steel, Fritsch, art. 14433410Fritsch
LABORETTE 24 vibratory feeder V-shaped trough, 100-120 V/1~, Fritsch, art. 24004000Fritsch
LABORETTE 24 Vibratory Feeder V-shaped Trough, 200-240 V/1~, Fritsch, art. 24003000Fritsch
PULVERISETTE 0 vibratory micro mill, Fritsch, art. 00602000Fritsch
Laborette 24 vibratory feeder U-shaped trough, 100-120 V/1~, Fritsch, art. 24001000Fritsch
LABORETTE 24 vibratory feeder U-shaped trough, 200-240 V/1~, Fritsch, art. 24002000Fritsch
Conversion kit for grinding larger quantities P-14 cl, Fritsch, art. 14351000Fritsch

Recently viewed

Questions about Mills, grinders & homogenisers

Which type of mill suits my sample: ball mill, rotor mill, cutting mill or jaw crusher?

A jaw crusher pre-crushes coarse, hard material. A rotor mill grinds soft to medium-hard samples quickly. A cutting mill handles fibrous, soft or moist material, such as plants and food. A ball mill or planetary mill grinds finest, down to the micrometre range. Several mills in sequence can give a better result for hard, coarse samples. Check the result with a test sieve; see test sieves and sieve shakers. Unsure which one fits? Ask sales@luminixhealth.com.

Which material should I choose for the grinding jar and balls?

Choose a material that is harder than your sample and contains no elements that would interfere with your analysis. Options include agate, zirconium oxide, tungsten carbide for very hard samples, hardened or stainless steel, and sintered corundum. For metal-free analysis, avoid steel, because abrasion would contaminate the sample. Clean the jar thoroughly between samples. Check the materials on the product page in mills, grinders and homogenisers. Need advice for your set-up? Mail sales@luminixhealth.com.

How many grinding balls, and which diameter, should I use?

Use larger balls for coarser feed material and smaller balls for a finer end result. The filling recommendation, meaning the number of balls per jar volume, is given in the manual of your mill or on the product page. Preferably choose balls and jar in the same material, so wear does not add a second contaminant. Do not overfill the jar. Balls and jars are in mills, grinders and homogenisers. For a quote or a second opinion, write to sales@luminixhealth.com.

When do I use a homogeniser instead of a mill?

A rotor-stator homogeniser works in liquid: it suits soft tissue, suspensions and emulsions, which it breaks up and disperses. A mill is for dry, solid materials that need to be reduced to powder. Some samples need both, first grinding and then dispersing in a solvent. For fine manual work, a mortar and pestle can be enough. Cool heat-sensitive samples during processing. See homogenisers and dispersers. Questions about a specific product? Contact sales@luminixhealth.com.

Why Mills, grinders & homogenisers?

A mill, grinder or homogeniser reduces particle size or breaks a tissue before an extraction. The rotor and the sieve insert decide the result. A knife mill and a bead mill are different machines. The sample has to tolerate the heat the motor puts into it.

A test sieve sorts particles by whether they pass an opening. Wire mesh and perforated plate are two ways of making that opening, and the nominal size is not a suggestion. A sieve shaker repeats the motion so the result does not depend on how hard someone shook by hand. A mill or grinder makes the particles smaller before they are sieved. The certificate of the sieve, and the opening size, are what an audit asks for. Measurement practice around mass and dimension sits with the BIPM, EURAMET and BELAC.

This shelf belongs to Test sieves & mills, inside Lab instruments. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?
How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?