Reaction vessels & jacketed vessels

Here you will find everything your laboratory needs for reaction vessels and jacketed vessels, such as: fractionating, vigreux column, lid flat flange, flat flange sealing and vacuum desiccator. This range is for biotech, hospitals, R&D, teaching and (quality) control. This collection holds 264 articles. The catalogue holds more than 150.000 articles. In-stock articles ship in two to five business days.

264 products

Showing 1 - 24 of 264 products

Showing 1 - 24 of 264 products
View
Attachment DN 100, centre neck NS 29/32, side necks NS 29/32 and NS 14/23, Witeg, art. 0944329Witeg
Attachment DN 60, centre neck NS 24/29, side necks NS 19/26, Witeg, art. 0942024Witeg
Attachment DN 60, centre neck NS 29/32, side necks NS 14/23, Witeg, art. 0942029Witeg
Attachment DN 150, centre neck NS 29/32, side necks NS 29/32, Witeg, art. 0942529Witeg
LR 1000 basic System, laboratory reactor, IKA, art. 0020119960IKA
LR 1000 control System, laboratory reactor, IKA, art. 0025001991IKA
HA.gv.dw.2, Double-walled glass vessel, for 2 l, IKA, art. 0020105974IKA
HA.gv.dw.0.5, Double-walled glass vessel, for 0,5 l, IKA, art. 0020106409IKA
HA.gv.dw.10, Double-walled glass vessel, for 10 l, IKA, art. 0020106414IKA
HA.gv.dw.1, Double-walled glass vessel, for 1 l, IKA, art. 0020106411IKA
HA.gv.dw.5, Double-walled glass vessel, for 5 l, IKA, art. 0020106413IKA
HA.cab.dw, cable and hose set for double-walled vessels, IKA, art. 0020107111IKA
Fractionating column according to Vigreux NS 24/29 with glass jacket, Witeg, art. 1522600Witeg
Fractionating column according to Vigreux with glass jacket, NS 29/32, 200 mm, Witeg, art. 1523200Witeg
Vigreux fractionating column PRECISO without glass jacket, NS 14/23, 200 mm, 11 rings, Witeg, art. 1520201Witeg
Fractionating column according to Vigreux PRECISO without glass jacket, cone NS 29/32, 200 mm, Witeg, art. 1523201Witeg

Recently viewed

Questions about Reaction vessels & jacketed vessels

Single-walled or jacketed reaction vessel: which do I need?

A single-walled vessel is heated or cooled from outside, in a bath or heating mantle. In a jacketed vessel, thermostat fluid flows through the outer jacket, which gives precise and even temperature control, also for exothermic reactions. A jacketed vessel needs a circulator to pump the fluid. Check the temperature range of the circulator against your reaction. Insulated hoses limit heat loss. See circulators, chillers and thermostats. For a quote or a second opinion, write to sales@luminixhealth.com.

Which flat flange size (DN) and lid go together?

Vessel, lid, sealing ring and quick-release clamp must all share the same DN size. Once that is fixed, choose the number and type of necks on the lid, either ground joints or screw threads, for stirrer, condenser and thermometer. Check the DN size on the product page. Write down the size before ordering spare parts. A worn sealing ring is best replaced at the same time. Matching parts are in ground joint glassware and condensers. Questions about a specific product? Contact sales@luminixhealth.com.

Which seal and clamp do I need for a flat flange vessel?

Place a sealing ring between vessel and lid, and close the joint with a quick-release clamp in the same DN size. A PTFE or PTFE-coated ring suits aggressive media; silicone is fine for general use. Check the ring for damage before each assembly, as a worn seal leaks vapour. Do not overtighten the clamp. Sealing products are in grease, boiling stones and sealants. Unsure which one fits? Ask sales@luminixhealth.com.

Which stirring system do I use in a reaction vessel?

An overhead stirrer drives a stirring shaft through a stirrer guide in the centre neck of the lid. The stirring element, such as an anchor, propeller or turbine, is chosen by viscosity and the mixing you need. Make sure shaft length and diameter match stirrer chuck and guide. Start stirring slowly. See overhead stirrers and stirring shafts, propellers and impellers. Need advice for your set-up? Mail sales@luminixhealth.com.

Why Reaction vessels & jacketed vessels?

A reaction vessel is the flask a synthesis actually runs in, sometimes jacketed so a fluid can heat or cool the wall. The joints, the working volume and the jacket connections are the specification. It is not a storage bottle.

A beaker is an open working vessel: easy to pour, poor as a measure. An Erlenmeyer flask has a flat base and a conical wall so a liquid can be swirled without climbing out. A round-bottom flask is for heating under a condenser, because the heat meets a curved wall and the joint at the neck connects to the rest of the glassware. Borosilicate is the glass that survives the temperature change. These forms are listed under ISO laboratory glassware.

This shelf belongs to Beakers & flasks, inside Labware. Luminix Health distributes this range for laboratory use.

Which shelves sit beside this one?

The neighbouring shelves are Round-bottom flasks, Beakers, Erlenmeyer flasks, Flat-bottom flasks, Flasks (other) and Beaker & flask accessories. The category above this shelf is Beakers & flasks.

How does ordering and shipping work?

Luminix Health distributes this range from the heart of Europe. We deliver across the EU in two to five days if in stock. Standard delivery is free from €250 excl. VAT. Cold-chain goods and dangerous goods under ADR are never included in that free delivery. The terms are in the Shipping Policy. Send a quote request, contact the team, or read who we are. The full brand index is on shop by brand.

Which other categories should I open?